Skip to main

Bosch MATRIX – OpenJDK Base64 Decoder Out-of-Bounds Write

BOSCH-SA-368530

Advisory Information

  • Advisory ID: BOSCH-SA-368530
  • CVE Numbers and CVSS v3.1 Scores:
  • Last Updated: 27 Nov 2026

Summary

On 17 November 2026, a memory corruption vulnerability in the OpenJDK Base64 decoder, known as "Java4Shell" (CVE-2026-114938), was publicly disclosed. On x86-64 processors supporting the AVX-512 VBMI instruction set, crafted malformed Base64 input with invalid padding can trigger an integer underflow (CWE-191) and an out-of-bounds heap write (CWE-787) of up to 62 bytes.

Bosch MATRIX is affected through its bundled Java runtime when operated on systems with affected x86-64 processors. An unauthenticated remote attacker able to supply untrusted Base64 data (for example, during authentication) could cause a denial of service (crash), disclosure of process/heap memory, or remote code execution. Systems with ARM-based processors or x86-64 processors without AVX-512 VBMI support are not affected. Bosch strongly recommends applying the available fix as soon as possible.

Affected Products

  • Bosch MATRIX Software 3000
    • CVE-2026-114938
      • Version(s): < 4.6
    • CVE-2026-114938
      • Version(s): 4.6.0 < 4.6.8
    • CVE-2026-114938
      • Version(s): 4.7.0 < 4.7.6
    • CVE-2026-114938
      • Version(s): 4.8.0 < 4.8.2
  • Bosch MATRIX Software 5000
    • CVE-2026-114938
      • Version(s): < 4.6
    • CVE-2026-114938
      • Version(s): 4.6.0 < 4.6.8
    • CVE-2026-114938
      • Version(s): 4.7.0 < 4.7.6
    • CVE-2026-114938
      • Version(s): 4.8.0 < 4.8.2
  • Bosch MATRIX Software 2000 EMA
    • CVE-2026-114938
      • Version(s): < 4.6
    • CVE-2026-114938
      • Version(s): 4.6.0 < 4.6.8
    • CVE-2026-114938
      • Version(s): 4.7.0 < 4.7.6
    • CVE-2026-114938
      • Version(s): 4.8.0 < 4.8.2
  • Bosch MATRIX Zeitwirtschaft für 100 MA
    • CVE-2026-114938
      • Version(s): < 4.6
    • CVE-2026-114938
      • Version(s): 4.6.0 < 4.6.8
    • CVE-2026-114938
      • Version(s): 4.7.0 < 4.7.6
    • CVE-2026-114938
      • Version(s): 4.8.0 < 4.8.2
  • Bosch MATRIX Zeitwirtschaft für 50 MA
    • CVE-2026-114938
      • Version(s): < 4.6
    • CVE-2026-114938
      • Version(s): 4.6.0 < 4.6.8
    • CVE-2026-114938
      • Version(s): 4.7.0 < 4.7.6
    • CVE-2026-114938
      • Version(s): 4.8.0 < 4.8.2

Solution and Mitigations

Solution

Apply the fix as soon as possible using one of the following options:

  1. Run the configuration fix tool (recommended for immediate remediation and for all versions): Execute the provided Windows fix tool matrix-java4shell-fix_windows-x64.exe on the Bosch MATRIX server. The tool applies a configuration change that mitigates the vulnerability and works for all Bosch MATRIX versions, including versions that are no longer maintained. During execution, the MATRIX service is stopped and automatically restarted. Note: A Microsoft Defender warning stating that the publisher could not be verified may appear; this warning can be safely ignored to run the tool.
  2. Update Bosch MATRIX to a fixed regular release: The same fix is included in the regular maintenance releases (no separate security-only patches are planned):
    • Bosch MATRIX 4.6.8 or later
    • Bosch MATRIX 4.7.6 or later
    • Bosch MATRIX 4.8.2 or later

For Bosch MATRIX 4.5 and earlier, no fixed release is currently available. Apply the fix tool (matrix-java4shell-fix_windows-x64.exe).

Upgrading to a newer software version may require an active Software Maintenance Agreement (SMA). This requirement does not apply to the standalone security patch / fix tool (matrix-java4shell-fix_windows-x64.exe).

How to obtain the patch / fix tool: Please contact the ZuKo Hotline to obtain the fix tool or update package. The contact details for the ZuKo Hotline can be viewed directly in Bosch MATRIX.

Mitigation

If the fix tool or software update cannot be applied immediately:

  • Restrict network access to the Bosch MATRIX server using firewalls and network segmentation (isolate the server in a trusted internal network and block access from untrusted networks or the internet) to prevent unauthenticated attackers from reaching endpoints that process Base64 input.
  • Check whether the host server's processor supports the AVX-512 VBMI instruction set; systems without AVX-512 VBMI (or on ARM processors) are not affected. If processor support cannot be determined, assume the installation is affected.

Because matrix-java4shell-fix_windows-x64.exe applies a configuration change only and works across all MATRIX versions without a full upgrade, applying it immediately is strongly recommended.

Vulnerability Details

CVE-2026-114938

CVE Description: Vulnerability in the Oracle Java SE, Oracle GraalVM for JDK, Oracle GraalVM Enterprise Edition product of Oracle Java SE (component: Compiler). Supported versions that are affected are Oracle Java SE: 8u511b33-perf, 17.0.21.0.3, 21.0.13.0.3, 25.0.5.0.3, 27.0.1.0.3; Oracle GraalVM for JDK: 17.0.21.0.3 and 21.0.13.0.3; Oracle GraalVM Enterprise Edition: 21.3.20.0.3. Difficult to exploit vulnerability allows unauthenticated attacker with network access via multiple protocols to compromise Oracle Java SE, Oracle GraalVM for JDK, Oracle GraalVM Enterprise Edition. Successful attacks of this vulnerability can result in takeover of Oracle Java SE, Oracle GraalVM for JDK, Oracle GraalVM Enterprise Edition. Note: This vulnerability can only be exploited by supplying data to APIs in the specified Component without using Untrusted Java Web Start applications or Untrusted Java applets, such as through a web service. CVSS 3.1 Base Score 8.1 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).

Remarks

Security Update Information

With respect to Directive (EU) 2019/770 and Directive (EU) 2019/771 and their national transposition laws, please note:

It is your responsibility to download and/or install any security updates provided by us, for example to maintain product or data security. If you fail to install a security update provided to you within a reasonable period of time, we will not be liable for any product defect solely due to the absence of such security update.

Alternatively, we are entitled to directly download and/or install security updates regardless of your settings. In these cases, we will provide you with the relevant information, e.g. in this security advisory.

CVSS Scoring

Vulnerability classification has been performed using the CVSS v3.1 scoring system. The CVSS environmental score is specific to each customer's environment and should be defined by the customer to attain a final scoring.

Additional Resources

Revision History

  • Nov 27, 2026: Initial Publication

Appendix

Material Lists

Bosch MATRIX

Family Name CTN SAP#
Bosch MATRIX Software 3000
QAC-MTX-3000
F.01U.569.235
Bosch MATRIX Software 5000
QAC-MTX-5000
F.01U.569.236
Bosch MATRIX Software 2000 EMA
QAC-MTX-2000
F.01U.591.875
Bosch MATRIX Zeitwirtschaft für 100 MA
QTC-MTX-EMP100
F.01U.579.309
Bosch MATRIX Zeitwirtschaft für 50 MA
QTC-MTX-EMP50
F.01U.586.811